I have a maxi-flo 2 and it just stopped working. Pump motors are not normally on a GFCI breaker, unless your pump plugs in to an outlet. On a DE filter, water enters the tank through the bottom tank bulkhead, and is when the tank fills up, water is forced through the grids, and then up thru the manifold, and down the standpipe to the top exit bulkhead DE inside the grids, must have been missing an o-ring before, a push-pull valve plunger ring? 2. loose pipe coming into pump, drawing air around fitting threads Ours is doing the same thing. I have a Hayward pro max 1.5hp with sand filter but the suction into basket is not good. Im not sure how the filters went bad being winterized, but they were way old. Any ideas? AquaRite not displaying t-xx and getting inspect cell and check salt, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. Make sure that the fitting that goes into the pump has no air leaks, which is the most common air leak area. My mistake was forgetting to empty pump basket. For Use With: Hayward AquaTrol Pool Chlorine Generator Brand: HAYWARD REVIEWS Q&A Powered by TurnTo Review More Purchases | My Posts There are no reviews for this item. Copyright 2022 In The Swim. I open the plastic door, fill with water and sometimes need to do this several times in order for it to keep going. We had a pool built in FL in Aug 2018 with variable speed Hayward TriStar pump. If it is still making chlorine and no real faults are flashing on the control, I wouldnt be too worried about it. I put my old AO Smith original bearing screaming unit in FULLY primes pushes all the air out runs fine. any ideas? When the pool guy switched it, it worked very well for about a month with no issues at all. It has been in operation since mid May without and incident before yesterday. If theres no power at the switch/timer, go back further to the breaker. If your new pump is the exact same make/model/horsepower as the old pump, then the pump is not the problem but if you switched make/models check the pump flow curve, because even though it may be the same hp, different make/model pool pumps produce Vastly different flow rates. Hi Dave..your honest opinion please..new 14000gal gunite pool with hayward sp3400vsp pump September 2014,ran a month winterized and ran fine for 3 years, when company came to open up the pool in 2017,pump stuck,installed new 3400@ $1200. Thanks for the help troubleshooting it. The pump has two drain plugs and the filter has one drain plug, all located on the bottom. For this issue you are having, I would bump and drain the filter of the DE powder and add a recharge of DE powder thru the skimmer, and give it another go. (This pump is on a regular 20 amp circuit breaker, not a GFCI.). Any ideas on how to fix this issue?? LibriVox is a hope, an experiment, and a question: can the net harness a bunch of volunteers to help bring books in the ' '' ''' - -- --- ---- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- Occasionally the salt level on the Hayward Aqua Rite may not match the actual salt level of the pool. ' Has more of an impeller type sound. Hi I have a variable speed ecostar and am now having the drive error, drive stalled. I would think that going to 1 hp superpump, from a 1.5 hp superpump, would not be a problem. I have a Hayward Self Priming Super Pump Model # C48J2N131B1. When the problem is after the pump impeller, like a clogged filter, closed return valve or clogged return line, the pressure will be higher than normal. "dateModified": "2/24/2015",
The best way to attack this is with the mantra the problem lies where the power dies. Hi Heidi, it sounds like maybe the plumbing could be reversed? Products, Learn About It did never tripped during program. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide"
This year, I noticed at times that the flow rate on low speed is less than it was last year. Yours may have become weak, or damaged somehow. Tried to vacuum. You may be able to remove the basket and reach thru the volute to the eye of the impeller, and may be able to feel debris. Any suggestions? i have an in ground pool. Probably not a pump or motor problem (but could be). Is there something special I need to do when first installing the motor? They do not seem to have enough stooch even though they are rated at 1HP like my original motor. If the pump is not grounded correctly, might that have something to do with it tripping? There is also a leak somewhere in the system because there is water on the pad. If thats not the issue, is the pump sized correctly for the filter, and not under/over sized? So if the water flow thru the unit is normal then I would next assume a bad flow switch or sensor (depending on what type of pool equipment we are talking about pump, salt cell, heater). First eliminate water flow issues, then gas flow issues, and finally the low voltage electric currents that run between pool heater components. Armstrong Human Resource Management 13th Edition Pdf, If power is tested at these points, I would check the motor terminals. . The stationary switch copper tabs may be bent, or may have a wire crossing between them, have a loose screw or have some other issue that prevents it from opening, and releasing the capacitor. Step 2: Verify the accuracy of the salt readings (2700-3400 pm) with an independent test kit or by taking a water sample to your local pool store for testing. It appears to be stuck. Reconnect the pipes and test it out! After we run the pump for a few minutes and then take the pump apart there is water in the impeller- but the water is where the seat housing is. My pump motor does not start until I spin the shaft then it runs for about 15 min and shuts off and I can hear the motor humming and it feels very hot to the touch. If I try to shut it off, nothing happens. They have to stick out about 1/8 wider than the plunger disk. Glad that you replaced the sand, normally lasts 5-7 years on larger sand filters, but filters below 21 diameter need it more often, and very small filters 12-14, need it almost every season. Almost ordered a new pump but it really sounded good. Hi Jennifer, many Matrix pumps have an on/off switch on the rear bottom of the motor cap end. Low speed should be enough flow to activate the flow switch. This usually means the motor needs to be replaced. No noise, nothing. Also, make sure you plug in the cell all the way. It had been running ok this summer. IF not, you may remove the motor end cap (with power off) and see that the wires are connected firmly. I would suggest replacing the pump with the same exact pump, which is matched to your filter size presumably. Hi Deb, probably a bad outlet or a bad cord, or a loose connection on one or both of those. Im being advised by an electrician that my Hayward pump has a dead short in it. Diffuser broke. Cheers! I have a dual flow 2 speed pump. Hi Julie, is the FLO error code on the heater? To remedy this, simply open up your pump, and clean out any rubbish. Please advise. Full membership to the IDM is for researchers who are fully committed to conducting their research in the IDM, preferably accommodated in the IDM complex, for 5 We would like to show you a description here but the site wont allow us. And 93, thats just the temp of the water, the flames are much hotter of course, thats what is melting the plastic. Shut off the breaker, and timer, and check the tightness of all screws on timer and on pump motor. I noticed the on/off switch seemed loose and when I took of the end case, the male disconnect to the switch was burned out. Using a circuit tester, I determined that the timer and the inline switch has power. If I block the outflow from it, it stops clicking on and off, and runs smoothly. So My pool pump is two speed and I have it set to run for 3 hours in low speed and 5 in high. Hi Rod, if the pump motor was submerged, then it is D.O.A. All components of the Aqua Rite System are showing good readings and appears to be all set correctly. },
When I then switch the pump breaker off and then back on again it springs into life (every time). . The air may be there on high speed too, its just not noticeable. Whenever Ive seen that its from too much voltage, like connecting 220V to a motor wired for 110V. with UV, Ozone and Hydroxyl Radicals. Not it says drivererror pump stalled. Spillover is just the spa filling up, and overflowing into the pool, a waterfall feature is something different, with dedicated plumbing and a booster pump usually. Checked the circuit breaker and turned it off and on. Is the replaced pump and motor problem? The outlet has been replaced and the issue is still happening. goes on first, then the spring, then the slightly larger hole washer. Attach a bond wire to the Eco star drive pump or tighten the loose screws on the bottom of the motor. I let the pump cool down, then reset the thermal switch and it runs for another hour and shuts off again.The wiring is the same and it doesnt trip the breaker switch. Now what? Filters, Learn About Reset the average salt level on startup and whenever you replace your cell. Salt cells create cloudy bubbles, Ozonators too. Check the incoming voltage to be sure that you are within the range of 110V-125V. I was only able to read and yes feel voltage in the pool when the main pump was running only. Hi, my above ground pool pump will run when not attached to the pool and there is no water in it, but when I get it hooked up to the pool and let the hoses and pump fill, it no longer turns on. The problem lies, where the power dies could be the breaker, time clock, outlet or at the terminal board. hayward blue essence troubleshooting. dr myers ultrasound. It feels like its not doing what its supposed to do. type of, Kreepy type swimming pool cleaners - known as Suction Side Cleaners, are the simplest type of pool cleaner, and hence one of, Polaris Pool Cleaner Tune-Up Instructions I took a drive around the Beltway last weekend and opened cousin Joe's pool in Chevy Chase,, Troubleshooting Hayward Gas Heater Error Codes, Swimming Pool Covers: The Good, The Bad, The Ugly, Pool Cleaner Tune-Up Kreepy Type Pool Cleaner repair, https://www.google.com/search?client=firefox-b-1-d&q=hayward+h-150+manual, https://www.afternic.com/forsale/haywarddocs.info?utm_source=TDFS&utm_medium=sn_affiliate_click&utm_campaign=TDFS_GoDaddy_DLS&traffic_type=TDFS&traffic_id=GoDaddy_DLS. Hi Rick, if thats a new thing, there is probably something loose and leaking (air) when the pump shuts off. It works fine otherwise, but the only way to stop it from heating up to 104 is by turning the power off to the heater. Any new postings here are unlikely to be seen or responded to by other members. Does it only do this when vacuuming, but otherwise runs fine? My Hayward xstream filter pump is not turning on at all. When I turned off the pump I saw that it spit a little bit of water out of a Jandy Valve. My pump seems to be working fine but Im having an issue with the flow pulsating out of the filter. Ive tried the override, checked the basket on the pump and felt into the intake and outlet for obstructions. Second be sure that you are delivering 230V (+/- 10%) and that the motor is set to accept 230V (some are reversible to accept 115V too). "name": "In The Swim",
Increased flow this year may be from the new sand, and higher flow makes it easier for air leaks to appear. A longstanding legal battle over control of the old Apex Department Store properties in Pawtucket appears to be headed.. Apex Legal Funding is a lawsuit financing company that provides pre settlement funding and post settlement funding to plaintiffs. Hayward recommends 1.5 PVC pipe, and more than one line, (i.e. My check salt generator station even after I clean it out. Drain plugs, pump lid, pipe coming into pump, skimmer or main drain valves, low water level, stuck skimmer weir, or the dreaded underground cracks in pipe (rare problem). There should be no continuity. Most Common areas include the pump lid (must be very tight, with lubed lid o-ring), and the threaded pipe that comes into the FRONT of the pump (must be very tight and sealed if loose, use Pool Putty to fix, or replace the fitting) the effluent or exit pipe fitting leaking will not draw air, that is on the pressure side not the suction side. Students and professors will find thorough, current coverage of all business research topics presented with a balance of theory and practical A Answered on 5/26/2022 by InyoPools Product Specialist Craig C.. Hello J. LibriVox About. Still the same results. I recently noticed what appears to be a shaft seal leak. Put it in the line at the pool, and as the pump begins to catch prime, crimp the hose and slowly pull out of the pipe. Since you didnt say it trips a breaker, its probably not a short or ground-out of power, although it still could be, typically a wire touching metal other than the terminals on both end of the wire. It got very wet and tripped the breaker. I connected Line 1&2 plus bond. They function as the starting battery for the motor, to help it get up to speed quickly. I think it only screws on in one direction, but unscrew it to check When in Filter Position, water should route in only one direction. Humming Motor: If the pump motor makes a humming sound when starting up, you likely have a clogged impeller. Hi Kathy, the clicking could be the start switch in the rear of the motor, not fully disengaging. But, you know whats not great? Also that some circuit breakers used can create such noise as to cause problems with this error message. So i contacted them and waiting for response but tempted to just get another replacement to keep circulation in pool because i just drained and refilled pool 5 days ago and running a waterfall pump to get some circulation and watching chlorine level. If the shaft does spin fine, and is not locked up, you can try a new capacitor, or check your current cap, with an ohmmeter. On a Hayward pump with clogged impeller, you can remove the basket, reach through the small hole with your fingers (pump off! Terrible storms 2 nights ago. Then recharge with a good dose of DE powder. It appeared that I couldve pulled them right off if I tried. A common mistake is to install the spring seal half backwards. When it comes to troubleshooting Hayward pool heater error codes, theres not too much difference between the problem solving process for other gas-fired heaters, made by Jandy, Pentair or Raypak. The Aqua Rite runs at maximum out for for the remainder of the current pump cycle or for 24 hours, whichever comes first. I came back after going out and my older Hayward pump was off. It shouldnt be overheating, not in twenty seconds, but I suppose it could. If it still trips the breaker, it may have shorted out the motor windings, and is not repairable. Hi, Lighting, Learn About Before you test your capacitor, take note of its appearance. Tough one, good luck! If it is reversible is lists voltage on the label as 115V/230V, but if 230V only, it just says 230V. what could be the issue? The correct replacement would be the AquaRite Main PCB (OEM) GLX-PCB-RITE. Any tips on getting the cover off to get to the capacitor (after removing the two screws)? EC65 uses 6 lbs, and EC75 uses 9 lbs, but since DE is half as light as others a lb of DE powder is more than 2 cups of dry measure, its actually closer to 4 cups. Could this be true? If it is new, you may have undersized the cell, or your water chemistry is imbalanced, preventing the chlorine from working efficiently and effectively. Be sure that bare wires are not touching other bare wires or terminals, or other metals. Remove the back of the motor and look for anything loose wires, switches, tabs. Pump lid not on tight enough Its likely good advice you are getting. Also will need to have clean pump basket and a clean pool filter, to ensure adequate flow rates. Possibly an obstruction on the return line, after the filter? To view these documents, you will need to download the free Acrobat Reader, which Any ideas why this would happen? Hi LInda, humming or buzzing, and not starting could be a few things first check that the shaft is spinning, either by spinning on the impeller end, or at the rear of the motor (power Off in both cases), to be sure the shaft is not bound up or seized. Fault with the pump wiring. 2017). What possibly is happening, is that air is being sucked in, possibly from low water level or a stuck skimmer weir, or an air leak in front of the pump (before the pump). I have a new Power-Flo Matrix pump. How do I get the lid tight enough? Hi Deb, SF (Sensor Failure) indicates that the temperature sensor (thermistor) is not getting good data to the circuit board. ? "mainEntityOfPage": "https://blog.intheswim.com/hayward-pool-pump-troubleshooting/",
Replace with exact MFD number, printed on side. We are headquartered in Valley Stream, New York, just outside of New UNK the , . Grass clippings, seeds, gravel or other small debris can clog an impeller and reduce suction. Mark. Anyone have this issue or have any recommendations? Set the test meter to Ohms, of 1K or higher. When I turn on my pump it runs normal for 5 seconds thank it winds down then reverts back to normal speed. The Pool is a Roman 23 in ground. If you havent inspected your cell yet, now is aperfect time. Something about level of placement of pump in relation to the water surface. My client thinks the motor was 1hp, but he really not sure. With the information explained in this comprehensive troubleshooting guide, you can diagnose and repair your Hayward single speed or variable speed pool pump with ease! Hi again, I dont have a shaft seal replacement video, but there are many on youtube. service center location, advanced Approx. (or 110V, if wired 120V). Sometimes this can be cleared or removed, without pulling the pump apart, which is def. Anyone have similar problems or have an idea what we r doing wrong? HI Sang, check the capacitor, or just replace it, they are cheap, it is the large black cylinder at 9 oclock in the rear of the motor. I have opened a pool and I have kept pump running 24 hrs due to Alge but few hours later there is no water moving in pool. Hi Marshall, check that the water level is good, and skimmer weirs are not stuck, blocking water flow into the skimmer, both cases cause the skimmer to suck air, which cause the pump to lose prime. I put a new power cord socket in the water proof box, which feeds power to the pump, I shined up the power cord plug pins), (power cord is about 2.5 ft of 12 Ga, not wet, not laying on the ground) Any suggestions? Does the panel just need to dry or did I cause possible damage? Improper voltage wiring is the usual culprit for smoking pump motors. I am getting air bubbles coming from my return jets in my pool. What you have to do is drain the filter and remove all those tiny bolts, and pull out the entire nest assembly. For AquaRite, move the switch from auto to off and check all of the readings. I have purchased a Hayward SP 158015 Power-floLX series 1 1/2 horsepower Above Ground pool pump along with a Hayward S166T Proseries sandfilter 16 inch top mount for a 15 ft above ground proseries pool. If you have power there, and the motor is making no sound then I would inspect closely for a loose wire on the terminal board, or a loose switch in the back, or loose capacitor wire. Hi Robin, an F5 code? Might be 2-years here is a chart on reading Hayward serial numbers, to find date of manufacture https://www.totallyhayward.com/techservices/attachments/Serial%20Number%20Read%20REVISED%201-2012.pdf, I have to reprime my hayward pump everytime I turn it on. There could also be a short in the wiring to the pump, or from the breaker to the switch.